- Manuals
- Brands
- Mitsubishi Electric Manuals
- Controller
- CITY MULTI PAR-40MAAU
- Quick start manual
Also See for PAR-40MAAU:
- Instruction book (224 pages) ,
- Installation manual (88 pages)
Advertisement
Table of Contents
- OPERATION/DISPLAY
- SCHEDULE AND TIMER SETTING
- RESTRICTION SETTINGS
-
SYSTEM EXAMPLE
-
MISCELLANEOUS ITEMS
-
ENERGY SAVING OPTION
-
DIMENSIONS
-
COMPATIBILITY CHART
-
SPECIFICATIONS
- Videos
-
Mitsubishi PAR-40MAAU - Basic Operation video
-
-
Documents / Resources
-
References
-
Download manual
-
Contents
- 1 OPERATION/DISPLAY
- 2 SCHEDULE AND TIMER SETTING
- 3 RESTRICTION SETTINGS
- 4 SYSTEM EXAMPLE
- 5 MISCELLANEOUS ITEMS
- 6 ENERGY SAVING OPTION
- 7 DIMENSIONS
- 8 COMPATIBILITY CHART
- 9 SPECIFICATIONS
- 10 Videos
- 10.1 Mitsubishi PAR-40MAAU - Basic Operation video
- 11 Documents / Resources
- 11.1 References
- 11.2 Download manual
Mitsubishi PAR-40MAAU Deluxe MA Remote Controller User Guide
FULL VIEW
BASIC VIEW
OPERATION/DISPLAY
- ON/OFF
- Switches between ON and OFF.
- Operation mode switching
- Switches between Cool/Dry/Fan/Auto/Setback/Heat.
- Hold
- Switches between enable and disable the Hold function.
- If the Hold function is enable, the following functions will be prohibited.
- ON/OFF timer/Schedule (Weekly timer) /Auto return/Auto-OFF timer
- Temperature setting
- Changes the set temperature.
- Set temperature range varies depending on the indoor unit model.
- Fan speed setting
- Changes fan speed.
- Available fan speeds vary depending on the model.
- Air flow direction setting
- Changes airflow direction.
- Available airflow directions vary depending on the model.
- Louver setting
- Switches between louver ON/OFF.
- Ventilation equipment control
- Interlocked setting and interlocked operation setting with City Multi Lossnay units can be performed.
- The Stop/Low/High settings of the ventilation equipment can be controlled.
- Main display mode setting
- The Main display can be displayed in two different modes: "Full" and "Basic."
- B&W inversion
- The colors of the display can be inverted, turning white background to black and black characters to white.
- Clock *2
- Date (year/month/day) and time (hour/minute) can be set.
- The set time as well as the day of the week will be displayed on the Main display.
- It is also possible for the time to not display on the main display.
- The clock can be displayed in 12-hour format (AM/PM before or after the time) and 24-hour format.
- Daylight saving time
- The start/end time for daylight saving time can be set.
- The daylight saving time function will be activated based on the setting contents.
- Room temp. display
- The room temperature display can be enabled or disabled.
- Error information
- When an error occurs, an error code and the unit address appear.
- The air-conditioning unit model, serial number, and contact number can be set to appear when an error occurs. (The above information needs to be entered in advance.)
- Filter information
- A filter sign will appear when it is time to clean the filter.
- Remote controller information
- The version of the remote controller can be checked.
*1 This function is active only for the units that support the function.
*2 The clock is accurate within 45 seconds per month (at the temperature of 77°F [25ºC]).
The clock is backed up for 3 days.
SCHEDULE AND TIMER SETTING
- Timer
- ON/OFF timer
- Turns ON and OFF daily at a set time.
- Time can be set in 5-minute increments.
- It is also possible to set the ON time only or the OFF time only.
- Auto-OFF timer
- Turns off the unit after a certain period of operation.
- Operation time can be set to a value from 30 to 240 minutes in 10-minute increments.
- ON/OFF timer
- Weekly timer
- Weekly ON/OFF times and set temperatures can be set.
- Time can be set in 5-minute increments. Up to 8 schedule patterns can be set per day of the week.
- Not valid when the ON/OFF timer is set.
RESTRICTION SETTINGS
- Allows/disallows local operation
- The following operation can be prohibited by applying certain settings on the centralized controller: ON/OFF, operation mode, set temperature, filter sign reset, air direction, fan speed and timer.
- While an operation is prohibited, the operation icon lights up (only on the Main display in the "Full" mode).
- Operation lock
- The following operations can be prohibited: Sensing Location, ON/OFF, Mode, Set temp., Menu, Fan, Louver, Vane, or Hold
- Temperature range restriction
- The room temperature range for each operation mode can be restricted.
- Auto return
- The units operate at the preset temperature after a designated period.
- Time can be set to a value from 30 to 120 minutes in 10-minute increments.
- Not valid when the temperature setting range is restricted.
- The units operate at the preset temperature after a designated period.
- Password
- Administrator password (required for schedule setting etc.) and Maintenance password (required for test run and function setting etc.) can be set.
SYSTEM EXAMPLE
*When a PAR-40MAAU is connected to a group, no other MA remote controllers can be connected to the same group.
MISCELLANEOUS ITEMS
- Language Selection
- Select the display language from the following 3 languages.
- English, French, Spanish
- Select the display language from the following 3 languages.
- Brightness Contrast
- The brightness of the LCD can be adjusted. The contrast of the LCD can be adjusted.
- Manual Vane Angle *1
- Fixes the vane position for each air outlet.
- Service *1
- Contains Test run, Function setting, Request code, and Error history.
- 3D i-see Sensor
- Settings for 3D i-see Sensor can be made.
ENERGY SAVING OPTION
- No occupancy energy save
- Requires 3D i-see sensor on applicable indoor units
- Room Occupancy energy save
- Requires 3D i-see sensor on applicable indoor units
- No occupancy Auto-OFF
- Requires 3D i-see sensor on applicable indoor units
- Setback Mode
*1 This function is active only for the units that support the function.
*2 The clock is accurate within 45 seconds per month (at the temperature of 77°F [25ºC]).
The clock is backed up for 3 days.
DIMENSIONS
Front View
Side View
Rear View
Unit: mm [in.]
COMPATIBILITY CHART
CITY MULTI® | M-Series | P-Series | |||
PMFY-NBMU | Yes | MFZ-KA | MAC-334 | PCA | Yes |
PEFY-NMU | Yes | MFZ-KJ | MAC-334 | PEA | Yes |
PEFY-NMAU | Yes | MSZ/Y-A | No | PEAD | Yes |
PEFY-NMHSU | Yes | MSZ/Y-D | NA: No NA-8: MAC-334 | PKA | Yes |
PEFY-NMLU | Yes | MS-WA | No | PLA | Yes |
PEFY-NMSU | Yes | MSZ-FD | No | PVA | Yes |
PLFY-NAMU | Yes | MSZ-FE | 09(12)NA: No 09(12)NA-8: MAC-334 18 NA: Yes1 | ||
PLFY-NBMU | Yes | MSZ/Y-GE | 06(-18)NA: No NA-8: MAC-334 NA-9: MAC-334 GE24NA: MAC-334 | ||
PLFY-NCMU | Yes | MSZ/Y-GL | MAC-334 | ||
PLFY-NEMU | Yes | MSZ-FH | MAC-334 | ||
PLFY-NFMU | Yes | MSZ-HE | No | ||
PLFY-NLMU | Yes | MSZ-HM | MAC-334 | ||
PCFY-VKM | Yes | MVZ-AA4 | Yes | ||
PCFY-NGMU | Yes | MVZ-AA7 | Yes | ||
PCFY-NKMU | Yes | SVZ-KP | Yes | ||
PFFY-NEMU | Yes | SEZ-KD | No | ||
PFFY-NRMU | Yes | SEZ-KD4 | Yes | ||
PVFY-E00 | Yes | SLZ-KA | Yes | ||
PVFY-NAMU | Yes | SLZ-KF | Yes | ||
PKFY-NAMU | Yes | MLZ-KP | MAC-334 | ||
PKFY-NFMU | Yes | Note: MAC-334 indicates that the unit requires a MAC-334IF-E Adapter in order to use the PAR-40MAAU | |||
PKFY-NGMU | Yes | ||||
PKFY-NBMU | Yes | ||||
PKFY-NHMU | Yes | ||||
PKFY-NKMU | Yes |
SPECIFICATIONS
Product size (W x H x D) | In. (mm) | 4 3/4 x 4 3/4 x 0.57 (120 x 120 x 14.5) |
Net Weight | Lbs. (kg) | 9/16 (0.25) |
Rated Power Supply Voltage | 12 VDC (supplied from indoor units) | |
Power Consumption | W | 0.3 |
Usage Environment | Temperature: 0 to 40º C (32 to 104º F) Humidity: 30 to 90%RH (with no condensation) | |
Material | Panel | PMMA |
Main body | PC + ABS | |
Sound Pressure Level | dB(A) | <70 [A-weighted sound pressure level] |
*1 Per Machinery Directive 2006/42/EC
© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Specifications are subject to change without notice.
M_ Submittal_PAR-40MAAU 03-2020
1340 Satellite Boulevard. Suwanee, GA 30024
Toll Free: 800-433-4822 www.mehvac.com
Videos
Mitsubishi PAR-40MAAU - Basic Operation video
Documents / Resources
References
Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Mitsubishi PAR-40MAAU Deluxe MA Remote Controller User Guide
Advertisement
Do you have a question about the PAR-40MAAU that isn't answered in the manual? Leave your question here.
Thank you! Your question has been received!
Related Manuals for Mitsubishi Electric PAR-40MAAU
-
Control Systems Mitsubishi Electric CITY MULTI PAR-40MAAU Instruction Book
Control system and m-series and p-series air conditioners (224 pages)
-
Remote Control Mitsubishi Electric CITY MULTI PAR-40MAAU Installation Manual
Ma remote controller (88 pages)
-
Controller Mitsubishi Electric PAC-YT51CRB Operation Manual
Multi control system and mr.slim air conditioners (6 pages)
-
Controller Mitsubishi Electric PAC-YT51CRB Installation Manual
City multi control systemand mr. slim air conditioners,simple ma controller (1 page)
-
Controller Mitsubishi Electric PAC-YT51CRB Installation Manual
City multi control system and mr. slim air conditionerssimple ma controller (1 page)
-
Controller Mitsubishi Electric SIMPLE MA PAC-YT51CRB Operation Manual
(3 pages)
-
Controller Mitsubishi Electric PAC-YT51CRB Installation Manual
Simple ma controller (8 pages)
-
Controller Mitsubishi Electric PAC-YT51CRA Installation Manual
City multi control system and mr. slim air conditioners simple ma controller (9 pages)
-
Controller Mitsubishi Electric PAC-SE51CRA User Manual
(3 pages)
-
Controller Mitsubishi Electric PAC-YG66DCA Instruction Manual
Air conditioner network system dido controller (16 pages)
-
Controller Mitsubishi Electric PAC-YG66 DCA-J Installation Instructions Manual
(16 pages)
-
Controller Mitsubishi Electric City Multi PAC-LV11M-J Installation Manual
Air conditioning systems connection kit (28 pages)
-
Controller Mitsubishi Electric PAR-U01MEDU Smart ME Instruction Book
City multi control system smart me controller par-u01medu (80 pages)
-
Controller Mitsubishi Electric PAR-F27MEA-US Installation Manual
City multi control system me remote controller (6 pages)
-
Controller Mitsubishi Electric ECODAN PAR-WT50R-E Operation Manuals
Wireless remote controller (16 pages)
-
Controller Mitsubishi Electric MELSEC iQ-F FX5 User Manual
Programmable controllers (180 pages)
-
Controller Mitsubishi Electric MELSEC iQ-F FX5 Programming Manual
Instructions, standard functions/function blocks (1112 pages)
-
Controller Mitsubishi Electric MELSEC iQ-F Series FX5 User Manual
Positioning control - intelligent function module (558 pages)
-
Controller Mitsubishi Electric MELSEC iQ-F FX5 User Manual
Modbus communication (86 pages)
-
Controller Mitsubishi Electric MELSEC iQ-F FX5 User Manual
Temperature control (180 pages)
Save Article as PDF